Technical center

These corrosion data are mainly based on results of general corrosion laboratory tests, carried out with pure chemicals and water solutions nearly saturated with air (the corrosion rate can be quite different if the solution is free from oxygen).

All concentrations are given in weight-% and the solvent is water if nothing else is shown. The corrosion data apply to annealed materials with normal microstructure and clean surfaces, throughout.

Ammonium perchlorate, NH4ClO4
Conc. NH4ClO4 10 10 20
Temp. °C 20 BP 30
Grade or type of alloy:
Carbon steel
13 Cr 2
Sandvik 1802 0 0 0 Risk of pitting and stress corrosion
Sandvik 3R12 0 0 0 cracking on stainless steels in
Sandvik 3R60 0 0 0 presence of chlorides.
18Cr13Ni3Mo 1)
0 0 0
17Cr14Ni4Mo 2)
0 0 0
Sandvik 2RK65 ('904L') 0 0 0
Sanicro 28 0 0 0
254 SMO 0 0 0
654 SMO 0 0 0
Sandvik SAF 2304 0 0 0
Sandvik SAF 2205 0 0 0
Sandvik SAF 2507 0 0 0
Titanium (CP Ti) 0 0 0

1) ASTM 317L, e.g. Sandvik 3R64
2) EN 1.4439, e.g. Sandvik 3R68