Datasheet updated

2024-01-11 10:32
(supersedes all previous editions)

Alleima® 6LR62 is a molybdenum-alloyed austenitic stainless steel.

Standards

  • ASTM: TP316, TP316H
  • UNS: S31600, S31609
  • EN Number: 1.4401
  • EN Name: X5CrNiMo17-12-2
  • W.Nr.: 1.4401
  • AFNOR: Z6ZND17-12

Chemical composition (nominal)

Chemical composition (nominal) %
C Si Mn P S Cr Ni Mo
0.05 0.6 1.5 ≤0.040 ≤0.015 17 11.5 2.1

Mechanical properties

At 20°C (68°F)

Proof strength Tensile strength Elong.
Rp0.2a) Rm Ab)
MPa ksi MPa ksi %
≥205 ≥30 515-790 75-115 ≥45

1 MPa = 1 N/mm2
a) Rp0.2 and Rp1.0 correspond to 0.2% offset and 1.0% offset yield strength, respectively.
b) Based on L0 = 5.65 √S0 where L0 is the original gauge length and S0 the original cross-section area.

At high temperatures

Metric units
Temperature
Proof strength
Rp0.2
°C MPa
min.
50 196
100 175
150 158
200 145
250 135
300 127
350 120
400 115
450 112
500 110
550 108
Imperial units
Temperature
Proof strength
Rp0.2
°F ksi
min.
200 26
400 21
600 18
800 16
1000 16
Creep strength
Temperature Creep-rupture strength
°C °F 10 000h 100 000h
MPa approx. ksi approx. MPa approx. ksi approx.
550 1020 255 37.0 177 25.7
575 1065 214 31.0 137 19.9
600 1110 172 24.9 108 15.7
625 1155 137 19.9 86 12.5
650 1200 108 15.7 64 9.3
675 1245 83 12.0 46 6.7
700 1290 64 9.3 33 4.8
725 1335 49 7.1 25 3.9
750 1380 37 5.4 18 2.6

Welding

The weldability of Alleima® 6LR62 is good. Welding must be carried out without preheating and subsequent heat treatment is normally not required. Suitable methods of fusion welding are manual metal-arc welding (MMA/SMAW) and gas-shielded arc welding, with the TIG/GTAW method as first choice.

For Alleima® 6LR62, heat input of <2.0 kJ/mm and interpass temperature of <150°C (300°F) are recommended.

Recommended filler metals

TIG/GTAW or MIG/GMAW welding

ISO 14343 S 19 12 3 H / AWS A5.9 ER316H

MMA/SMAW welding

ISO 3581 E 19 12 2 R / AWS A5.4 E316H-17


Disclaimer: Recommendations are for guidance only, and the suitability of a material for a specific application can be confirmed only when we know the actual service conditions. Continuous development may necessitate changes in technical data without notice. This datasheet is only valid for Alleima materials.