These corrosion data are mainly based on results of general corrosion laboratory tests, carried out with pure chemicals and water solutions nearly saturated with air (the corrosion rate can be quite different if the solution is free from oxygen).

All concentrations are given in weight-% and the solvent is water if nothing else is shown. The corrosion data apply to annealed materials with normal microstructure and clean surfaces, throughout.

Hydrofluoric acid, HF
Conc. %0.10.10.10.1
Temp. °C50607080
Grade or type of alloy:
Carbon steel
13 Cr
Alleima® 1802
Alleima® 3R12
Alleima® 3R60
18Cr13Ni3Mo 1)
17Cr14Ni4Mo 2)
Alleima® 2RK65 ('904L')0001
Sanicro® 28
254 SMO001
654 SMO0000
SAF™ 23040000
SAF™ 2205
SAF™ 25070000
Titanium (CP Ti)

1) ASTM 317L, e.g. Alleima® 3R64
2) EN 1.4439, e.g. Alleima® 3R68

Hydrofluoric acid, HF
Conc. %0.10.10.50.50.50.50.51111111020203075100
Temp. °C90100=BP3040506070203040506070201525153020
Grade or type of alloy:
Carbon steel2200
13 Cr2221
Alleima® 1802221
18Cr10Ni 1)1221
17Cr12Ni2.5Mo 2)
01221
18Cr13Ni3Mo 3)
0221
17Cr14Ni4Mo 4)
0221
Alleima® 2RK65 ('904L')101110111212221
Sanicro® 2800111
254 SMO110011001111122
654 SMO0100000000001
SAF™ 230420112
SAF™ 220512
SAF™ 25070101100012
Titanium (CP Ti)2222

1) ASTM 304L/304, e.g. Alleima® 3R12 and Alleima® 5R10, respectively
2) ASTM 316L/316, e.g. Alleima® 3R60 and Alleima® 5R60, respectively
3) ASTM 317L, e.g. Alleima® 3R64
4) EN 1.4439, e.g. Alleima® 3R68

Symbol clarification

These corrosion tables use a number of symbols, having the following meanings:

Symbol Description
0 Corrosion rate less than 0.1 mm/year. The material is corrosion proof.
1 Corrosion rate 0.1—1.0 mm/year. The material is not corrosion proof, but useful in certain cases.
2 Corrosion rate over 1.0 mm/year. Serious corrosion. The material is not usable.
p, P Risk (severe risk) of pitting and crevice corrosion.
c, C Risk (Severe risk) of crevice corrosion. Used when there is a risk of localised corrosion only if crevices are present. Under more severe conditions, when there is also a risk of pitting corrosion, the symbols p or P are used instead.
s, S Risk (Severe risk) of stress corrosion cracking.
ig Risk of intergranular corrosion.
BP Boiling solution.
ND No data. (Used only where there are no actual data to estimate the risk of localised corrosion instead of p or s).

Disclaimer: Laboratory tests are not strictly comparable with actual service conditions. Accordingly, Alleima makes no warranties, express or implied, and accept no liability, compensatory or consequential, for the performance of different materials in individual applications that may be based on the information provided in this publication.